سازه فولادی اسپیس فریم.Gas station قاب فضایی canopies provide a durable and visually clean roofing solution for fuel stations and service facilities. The three-dimensional frame can create wide column-free covered areas while accommodating lighting, signage, drainage and roofing systems. Bolt-ball connections allow modular fabrication and efficient installation. We customize the canopy according to site dimensions, column layout, roof shape, wind loads, drainage requirements and architectural appearance. Suitable roofing and finishing systems can be selected for different climates and operating environments. The structure can also be integrated with branding elements and lighting for a complete station canopy solution.
| مورد | Standard Description |
| نام محصول | سایبان قاب فضایی پمپ بنزین (Bolt-Ball Space Grid Structure) |
| Structure Type | 3D triangulated bolt-ball space grid; bolted spherical joints; no on-site welding |
| Main Steel – Tubes | Q235B / Q355B seamless steel pipe; common specs: Φ75.5×3.75, Φ88.5×4, Φ114×4, Φ140×5 (custom by design) |
| Main Steel – Nodes | Bolt balls made of forged 45# steel; high-strength bolts grade 10.9S |
| Accessories | مخروط ها, آستین ها, sealing/end plates, high-strength nuts, purlins, roof panels & fasteners |
| Typical Span | Single span 12–36 m; multi-span combined canopy can reach 40+ m (custom) |
| Grid Height / Rise | 1.8–3.5 m, designed according to span, slope and applied loads |
| Roof Enclosure | Color steel profiled sheet / insulated sandwich panel / aluminum cladding; optional skylight strip |
| Surface Coating | Standard: hot-dip galvanized; optional duplex system (galvanized + epoxy/primer + polyurethane topcoat) for coastal or corrosive sites |
| Design Loads | Wind load, snow load, roof live load, seismic load; calculated to local code (Eurocode / AISC / ASCE / گیگابایت / local standard) |
| Canopy Shape | Flat, single-slope, double-slope, curved or polygonal; custom to station layout |
| Fire Protection | Fire-retardant coating available, applied to meet local fire code |
| Design Service Life | ≥ 30–50 years under routine inspection and maintenance |
| Applicable Scenarios | Petrol / fuel / filling station canopy, gas station roof, forecourt cover, retail fuel station shade |
2.توانایی تامین
| Capability | Detail |
| Monthly Production Capacity | 200-300 tons per day (fill per order schedule) |
| Design Lead Time | 5–10 working days after drawing / parameter confirmation |
| Fabrication Lead Time | 20–35 days after deposit and final drawings approved |
| Minimum Order Quantity | 1 project (single canopy accepted); custom dimensions supported |
| OEM / Custom Design | Yes — we design per your span, loads, site conditions and station layout |
| Supply Scope | Structural design, fabrication of tubes / توپ های پیچ / accessories, packaging, export supply, installation guidance |
| Quality Documentation | Mill certificates, material test reports, coating thickness report, dimensional inspection records |
| Export Markets | خاورمیانه, Africa, آسیای جنوب شرقی, South America, Eastern Europe and other global markets |
| Installation Support | Assembly drawings, bolt torque list, on-site supervisor guidance available on request |
| مورد | Detail |
| Steel Members | Bundled by member number and size; each bundle labelled with project code and part ID |
| توپ های پیچ و مهره ای & Small Parts | Packed in strong wooden / plywood boxes; پیچ و مهره, مخروط ها, sleeves sorted and labelled separately |
| Roof Panels & برلین | Bundled and protected against scratching; edge and surface film preserved |
| Container Loading | 40HQ / 40GP containers; bundled members loaded and secured by straps; loading plan provided |
| Nearest Loading Port | Qingdao / شانگهای / Ningbo, or customer-nominated port |
| شرایط تجارت (Incoterms) | EXW / FOB موجود است |
| Payment Terms | T/T: 30% deposit, 70% before shipment; L/C at sight acceptable for large orders |
| Packing List & Documents | Packing list, commercial invoice, material certificates, inspection reports issued with shipment |
4.Drawings & Quotation — Fill in to Request a Quote
| Fill the yellow column; we will return the structural calculation, member list and quotation accordingly. | ||
| Required Parameter | Your Input | Remark |
| Canopy span (length along front), m | Horizontal length of the canopy facing the forecourt | |
| Canopy depth, m | Projection from support column line to outer edge | |
| Number of canopies / bays | Number of separate canopies or connected bays | |
| Total roof area, m² | Calculated roof area for panel and quantity estimation | |
| Grid height / roof rise, m | Truss depth or crown height; leave blank for designer to decide | |
| Local wind speed / بار باد | Design wind speed (m/s) or wind pressure (kN/m²), per local code | |
| Snow load | Design snow pressure (kN/m²), or confirm no snow region | |
| Seismic grade / zone | Seismic fortification intensity or seismic zone if required | |
| Roof panel type | Profiled sheet / sandwich panel thickness / color; skylight required? (Yes/No) | |
| Coating requirement | Hot-dip galvanized / duplex coating; coastal or corrosive environment note | |
| Country / destination city | For code check, freight and applicable standards | |
| Site drawing provided? | Yes — attached; No — need us to design from parameters | |
| Required delivery date | Target completion or shipment date | |
| Quotation basis (Incoterm) | EXW / FOB / CFR / CIF and target port | |
| Contact person | Buyer name for quotation | |
| ایمیل / WhatsApp / Phone | Contact channel for proposal and drawings | |

